Protocol analysis
R&S
®
RTP
607User Manual 1337.9952.02 ─ 12
Remote command:
TRIGger<m>:MILStd:DATA:ICONdition on page 1694
TRIGger<m>:MILStd:DATA:IMAX on page 1694
TRIGger<m>:MILStd:DATA:IMIN on page 1694
11-Bit Information
The 11-Bit information sets bits 9 to 19 if there is a command or status word. The 11-Bit
information consists of the condition and one or two 11-Bit information patterns.
In binary format, use the following characters: 1; 0; or X (do not care). To enter the pat-
tern in other formats use the bit pattern editor, see Chapter 13.1.7, "Bit pattern editor",
on page 519.
"Condition"
Sets the comparison condition to a specific value or a range.
"Info Min/Info"
Specifies the value or sets the start value of a range.
"Info Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
TRIGger<m>:MILStd:CDST:ICONdition on page 1692
TRIGger<m>:MILStd:CDST:IMAX on page 1693
TRIGger<m>:MILStd:CDST:IMIN on page 1693
Subaddress/ Mode
The subaddress/mode setup consists of the condition and one or two subaddress/
mode patterns.
In binary format, use the following characters: 1; 0; or X (do not care). To enter the pat-
tern in other formats use the bit pattern editor, see Chapter 13.1.7, "Bit pattern editor",
on page 519.
"Condition"
Sets the comparison condition to a specific value or a range.
"Subaddress Min / Subaddress/Mode"
Specifies the value or sets the start value of a range.
"Subaddress
Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
TRIGger<m>:MILStd:CMD:SCONdition on page 1691
TRIGger<m>:MILStd:CMD:SMAX on page 1692
TRIGger<m>:MILStd:CMD:SMIN on page 1692
Data Word Count/Mode Code
The data word count/ mode code setup consists of the condition and one or two pat-
terns.
In binary format, use the following characters: 1; 0; or X (do not care). To enter the pat-
tern in other formats use the bit pattern editor, see Chapter 13.1.7, "Bit pattern editor",
on page 519.
"Condition"
Sets the comparison condition to a specific value or a range.
"Word Count Min/ Count Code"
Specifies the value or sets the start value of a range.
MIL-1553 (option R&S RTP-K6)