Configuring the RF Signal
R&S
®
SMBV100B
316User Manual 1178.4460.02 ─ 03
Step / Extern Step mode (Sweep/List)
Figure 6-10: Step / Extern Step mode (sweep / list )
The instrument generates the signal step-by-step.
Starts signal generation with "State = On".
Switches to the next step with a manual action.
If the end value is reached, signal generation starts again from the beginning.
Stops signal generation with "State = Off".
Trigger sources:
The rotary knob at the front panel.
The [Arrow] keys at the front panel.
The corresponding remote control commands.
An externally applied trigger signal.
To step through the sweep frequencies or levels:
In manual mode:
Set the Current Frequency or Current Level values
Use the [Up] and [Down] keys or the rotary knob
In remote control mode:
Use the commands [:SOURce<hw>]:FREQuency:MANual or
[:SOURce<hw>]:POWer:MANual with the UP or DOWN parameter
Steps that would exceed the sweep range are ignored.