Configuring the RF Signal
R&S
®
SMBV100B
399User Manual 1178.4460.02 ─ 03
Filter Length..................................................................................................401
Auto Once.....................................................................................................401
Noise/Signal Ratio........................................................................................ 401
Timeout......................................................................................................... 401
Default Aperture Time...................................................................................402
Aperture Time............................................................................................... 402
S-Parameter .................................................................................................402
Enable Logging.............................................................................................402
Sensor type and serial number
Indicates the type and the serial number of the selected R&S NRP power sensor, and
the channel the sensor is assigned to.
The displayed Level (Peak) / Level (Average) values correspond to the particular sen-
sor.
Remote command:
:SENSe<ch>[:POWer]:TYPE? on page 661
:SENSe<ch>[:POWer]:SNUMber? on page 660
Level (Peak) / Level (Average)
Indicates the measured peak or average level value.
You can also change the unit for the results display: Watt, dBm or dBμV.
Note: Peak level measurements are provided if the power sensor supports this feature.
Remote command:
:READ<ch>[:POWer]? on page 654
:SENSe<ch>:UNIT[:POWer] on page 654
Sensor Mapping
Accesses the NRP Sensor Mapping dialog.
Sensor Settings
One tab per sensor provides the corresponding setting parameters.
State ← Sensor Settings
Activates level measurement.
Remote command:
:INITiate<hw>[:POWer]:CONTinuous on page 653
To query the availability of a sensor at a given connector, use the command :
SENSe<ch>[:POWer]:STATus[:DEVice]? on page 661.
Zero ← Sensor Settings
Activates the auto zeroing.
For details, see "About zeroing" on page 396.
Remote command:
:SENSe<ch>[:POWer]:ZERO on page 662
Display ← Sensor Settings
Sets the display mode for power readings.
Improving Level Performance