General Instrument Functions
R&S
®
SMBV100B
523User Manual 1178.4460.02 ─ 03
"Lev Att"
Output signal that determines whether the signal level is attenuated, if
envelope curve control is active.
The internal "Lev Att" control signal is defined in a control list and acti-
vated in the "Baseband > Custom Digital Modulation > Power Ramp
Control" dialog.
See also Chapter 3.5.3.8, "Control and Marker Lists Editor",
on page 130.
"Burst Gate"
Output for control signal for envelope curve control.
This control signal is defined in a control list and activated in the
"Baseband > Custom Digital Modulation > Power Ramp Control" dia-
log.
See also Chapter 3.5.3.8, "Control and Marker Lists Editor",
on page 130.
"Hop"
Marks the hop trigger for frequency hopping in the List mode for
"Custom Digital Modulation". The hop signal is defined in a control list
and activated by loading the control list, see Chapter 3.5.3.8, "Control
and Marker Lists Editor", on page 130.
"CW/Mod"
Output signal to indicate the output of RF signal in unmodulated form
(digital modulation is deactivated).
This control signal is defined in a control list, see Chapter 3.5.3.8,
"Control and Marker Lists Editor", on page 130.
"Triggered"
Output of the internal or the received external trigger signal.
"Manual Trigger"
Output of a short pulse signal that can serve as a common external
trigger signal for triggering of several R&S SMBV100B.
See Example "Triggering several R&S SMBV100B instruments simul-
taneously" on page 434.
"Always 0/Always 1"
Control signal with low or high level.
"None"
No signal is assigned to the connector.
Remote command: 
[:SOURce]:INPut:USER<ch>:SIGNal on page 678
:OUTPut:USER<ch>:SIGNal on page 679
Execute Trigger
If "User 5 > Direction = Output" and "Signal = Manual Trigger", generates a short pulse
signal and outputs it at the User 5 connector.
The signal can serve as a common external trigger signal for triggering of several
R&S SMBV100B, see Example "Triggering several R&S SMBV100B instruments
simultaneously" on page 434.
Remote command: 
:OUTPut:USER<ch>:TRIGger[:IMMediate] on page 679