EasyManua.ls Logo

Rohde & Schwarz SMBV100B - Page 653

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100B
651User Manual 1178.4460.02 ─ 03
Example: Performing a simple power measurement
Prerequisite: The sensor is connected to the instrument and mapped to the first sensor
channel.
:INITiate1:CONTinuous ON
//Switches the continous power measurement on
:READ1?
// Triggers the measurement and displays the results
Example: Performing a power measurement with a fixed filter
Prerequisite: The sensor is connected to the instrument and mapped to the first sensor
channel.
SENSe1:SOURce RF
//Sensor measures the power of the RF signal
SENSe1:FILTer:TYPE NSRatio
//Selects fixed noise filter mode
SENSe1:FILTer:NSRatio 0.02 DB
//Sets the maximum noise component in the result to 0.02 DB
SENSe1:FILTer:NSRatio:MTIMe 10
//Limits the settling time to 10 seconds.
:SENSe1:APERture:DEFault:STATe 0
// Deactivates the default aperture time of the sensor
:SENSe1:APERture:TIMe 10e-6
// Sets the aperture time to 10 us
SENSe1:UNIT DBM
//Selects unit dBm for the measured value
:INITiate:CONTinuous ON
//Switches the continous power measurement on
:READ?
//Triggers the measurement and displays the results
:SLISt[:LIST]?................................................................................................................ 652
:SLISt:SCAN[:STATe]......................................................................................................652
:SLISt:ELEMent<ch>:MAPPing........................................................................................653
:SLISt:SENSor:MAP.......................................................................................................653
:INITiate<hw>[:POWer]:CONTinuous............................................................................... 653
:READ<ch>[:POWer]?....................................................................................................654
:SENSe<ch>:UNIT[:POWer]............................................................................................654
:SENSe<ch>[:POWer]:APERture:DEFault:STATe.............................................................. 655
:SENSe<ch>[:POWer]:APERture:TIMe.............................................................................655
:SENSe<ch>[:POWer]:CORRection:SPDevice:SELect.......................................................655
SENSe, READ, INITiate and SLISt Subsystems

Table of Contents

Related product manuals