Loading...
Remote Control Commands
R&S
®
SMBV100B
684User Manual 1178.4460.02 ─ 03
Parameters:
<BbinIqHsChBb> NONE | A | B | C | D | E | F | G | H
*RST: NONE
Example: See Example "Applying an external digital baseband signal (HS
Dig I/Q)" on page 682.
Options: R&S SMBVB-B9
[:SOURce<hw>]:BBIN:CHANnel<ch0>:BB:STATe <BbinIqHsChanSta>
Activates the channel.
Parameters:
<BbinIqHsChanSta> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Applying an external digital baseband signal (HS
Dig I/Q)" on page 682.
Manual operation: See "BB" on page 461
[:SOURce<hw>]:BBIN:CHANnel<ch0>:NAME <BbinIqHsChanNam>
Queries the channel name.
Parameters:
<BbinIqHsChanNam> string
Example: See Example "Applying an external digital baseband signal (HS
Dig I/Q)" on page 682.
Manual operation: See "Name" on page 460
[:SOURce<hw>]:BBIN:CHANnel<ch0>:POWer:CFACtor <BbinIqHsChCrFac>
Sets the crest factor of the individual channels.
Parameters:
<BbinIqHsChCrFac> float
Range: 0 to 30
Increment: 0.01
*RST: 0
Example: See Example "Applying an external digital baseband signal (HS
Dig I/Q)" on page 682.
Manual operation: See "Crest Factor" on page 461
[:SOURce<hw>]:BBIN:CHANnel<ch0>:POWer:PEAK <BbinHsChPoPeak>
Sets the peak level per channel relative to full scale.
SOURce Subsystem

Table of Contents