Remote Control Commands
R&S
®
SMBV100B
765User Manual 1178.4460.02 ─ 03
Parameters:
<Mode> OFF | MIN | MAX
*RST: OFF
Example:
SOURce1:BB:ARBitrary:MCARrier:CFACtor:MODE OFF
Switches off automatic crest factor optimization.
Manual operation: See "Crest Factor Mode" on page 229
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLIPping:CFACtor <CFactor>
Sets the value of the desired crest factor, if baseband clipping is enabled.
A target crest factor above the crest factor of the unclipped multicarrier signal has no
effect.
Parameters:
<CFactor> float
Range: -50 to 50
Increment: 0.01
*RST: 50
Default unit: dB
Example: See [:SOURce<hw>]:BB:ARBitrary:MCARrier:
CLIPping[:STATe] on page 765.
Manual operation: See "Target Crest Factor" on page 229
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLIPping:CUToff <Cutoff>
Sets the cutoff frequency of the final low pass filter, if baseband clipping is enabled.
Parameters:
<Cutoff> float
Range: 0 to 250E6
Increment: 0.01
*RST: 75E6
Example: See [:SOURce<hw>]:BB:ARBitrary:MCARrier:
CLIPping[:STATe] on page 765.
Manual operation: See "Filter Cutoff Frequency" on page 229
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLIPping[:STATe] <State>
Switches baseband clipping on and off.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0