Remote Control Commands
R&S
®
SMBV100B
845User Manual 1178.4460.02 ─ 03
Parameters:
<Period> float
Range:  1E-6  to  100
Increment:  1E-8
*RST:  1E-3
Example:  See Example "Configuring the LF generator" on page 838.
Manual operation:  See "Period" on page 367
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:WIDTh <Width>
Sets the pulse width of the generated pulse.
Parameters:
<Width> float
Range:  1E-6  to  100
Increment:  1E-8
*RST:  5E-4
Example:  See Example "Configuring the LF generator" on page 838.
Manual operation:  See "Pulse Width" on page 367
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:FALL <Fall>
Selects the fall time for the trapezoid shape of the LF generator.
Parameters:
<Fall> float
Range:  1E-6  to  100
Increment:  10E-9
*RST:  250E-6
Example:  See Example "Configuring the LF generator" on page 838.
Manual operation:  See "Trapezoid Rise / Fall" on page 368
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:HIGH <High>
Sets the high time for the trapezoid signal of the LF generator.
Parameters:
<High> float
Range:  1E-6  to  100
Increment:  10E-9
*RST:  250E-6
Example:  See Example "Configuring the LF generator" on page 838.
Manual operation:  See "Trapezoid High" on page 368
SOURce Subsystem