:SYSTem:ERRor:STATic?
Returns a list of all errors existing at the time when the query is started. This list corre-
sponds to the display on the info page under manual control.
Return values:
<StaticErrors> string
Example: See Example "Querying the error queue" on page 890
Usage: Query only
Manual operation: See "Static Errors/Error History" on page 950
:SYSTem:ULOCk
<Mode>
Locks or unlocks the user interface of the instrument.
Parameters:
<Mode> ENABled | DONLy | DISabled | TOFF | VNConly
ENABled
Unlocks the display, the touchscreen and all controls for the
manual operation.
DONLy
Locks the touchscreen and controls for the manual operation of
the instrument. The display shows the current settings.
VNConly
Locks the touchscreen and controls for the manual operation,
and enables remote operation over VNC. The display shows the
current settings.
TOFF
Locks the touchscreen for the manual operation of the instru-
ment. The display shows the current settings.
DISabled
Locks the display, the touchscreen and all controls for the man-
ual operation.
*RST:
n.a. (factory preset: ENABled)
Example:
:SYST:ULOC DIS
Activates the user interface lock, including display and controls.
Manual operation: See "User Interface" on page 541
:SYSTem:DLOCk <DispLockStat>
Disables the manual operation via the display, including the front panel keyboard of the
instrument and the Local key.
Parameters:
<DispLockStat> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)