19 - 110
19EtherNet/IP COMMUNICATION
This instance supports the following services.
(a) When Ins ID is 0
Service Code
Name
Description
01h
Get_Attributes_All
Reads the values of all the attributes.
0Eh
Get_Attribute_Single
Reads the value of the specified attribute.
(b) When Ins ID is not 0
Service Code
Name
Description
01h
Get_Attributes_All
Reads the values of all the attributes.
05h
Reset
Calls the Reset service of the specified class/object.
0Eh
Get_Attribute_Single
Reads the value of the specified attribute.
10h
Set_Attribute_Single
Writes a value to the specified attribute.
(c) Reset
POINT
If the value of the reset type is set to "0" in the Reset service, parameter settings,
etc. are still written to the EEP-ROM. Note that the number of write times to
the EEP-ROM is limited to 100,000. If the total number of write times exceeds
100,000, the driver may malfunction when the EEP-ROM reaches the end of its
useful life.
The following table lists the reset types that can be used with the Reset service.
Value
Reset type
0
Emulate as closely as possible cycling power on the item the Identity Object represents. This value is the default if this
parameter is omitted. The network card, driver and MR-D30 functional safety unit do not restore the default values of each
parameter.
1
Return as closely as possible to the factory default configuration, then emulate cycling power as closely as possible. The
network card restores the default values of communication setting, such as an IP address. The parameters of the driver
and MR-D30 functional safety unit are reset to the factory setting.
The following set values of the driver can be rewritten with the factory setting.
Basic setting parameters ([Pr. PA_ _ ])
Gain/filter setting parameters ([Pr. PB_ _ ])
Extension setting parameters ([Pr. PC_ _ ]) (except [Pr. PC11] and [Pr. PC12])
I/O setting parameters ([Pr. PD_ _ ])
Extension setting 2 parameters ([Pr. PE_ _ ])
Extension setting 3 parameters ([Pr. PF_ _ ])
Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ])
Positioning control parameters ([Pr. PT_ _])
Network setting parameters ([Pr. PN_ _])

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals