General
6.3.6 NVM 742_Paper Handling List
Version 1.1
742-174 Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Extra Heavy-
weight)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-175 Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-176 Regi Assist Start Timing Adjustment
(MSI/126[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/126[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-177 Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Labels2)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Labels2)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-178 Regi Assist Start Timing Adjustment
(Tray 2/126[mm/s]/Plain)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-179 Regi Assist Start Timing Adjustment
(Tray 2/63[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-180 Regi Assist Start Timing Adjustment
(Tray 2/126[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-181 Regi Assist Start Timing Adjustment
(Tray 2/63[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Extra Heavy-
weight)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-182 Regi Assist Start Timing Adjustment
(Tray2/63[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-183 Regi Assist Start Timing Adjustment
(Tray2/126[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-184 Regi Assist Start Timing Adjustment
(Tray2/63[mm/s]/Labels2)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Labels2)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-185 Regi Assist Start Timing Adjustment
(Duplex/126[mm/s]/Plain);
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Duplex/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-186 Regi Assist Start Timing Adjustment
(Duplex/63[mm/s]/Heavyweight);
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Duplex/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-187 Regi Assist Start Timing Adjustment
(Duplex/126[mm/s]/Heavyweight);
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Duplex/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-188 Regi Assist Start Timing Adjustment
(Invert/126[mm/s]/Plain)
-18 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Invert/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-189 Regi Assist Start Timing Adjustment
(Invert/63[mm/s]/Heavyweight1)
28 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Invert/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-190 Regi Assist Start Timing Adjustment
(Invert/126[mm/s]/Heavyweight1)
-18 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Invert/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
Table 1 NVM 742_Paper Handling List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description
Write
Allowed/
Protected
Can be
initialized

Table of Contents

Other manuals for Fuji Xerox DocuCentre SC2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Xerox DocuCentre SC2020 and is the answer not in the manual?

Fuji Xerox DocuCentre SC2020 Specifications

General IconGeneral
BrandFuji Xerox
ModelDocuCentre SC2020
CategoryAll in One Printer
LanguageEnglish

Related product manuals