05/2014
6-49
DC SC2020
General
6.3.6 NVM 742_Paper Handling List
Version 1.1
742-174 Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Extra Heavy-
weight)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-175 Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-176 Regi Assist Start Timing Adjustment
(MSI/126[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/126[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-177 Regi Assist Start Timing Adjustment
(MSI/63[mm/s]/Labels2)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (MSI/63[mm/s]/Labels2)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-178 Regi Assist Start Timing Adjustment
(Tray 2/126[mm/s]/Plain)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-179 Regi Assist Start Timing Adjustment
(Tray 2/63[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-180 Regi Assist Start Timing Adjustment
(Tray 2/126[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-181 Regi Assist Start Timing Adjustment
(Tray 2/63[mm/s]/Extra Heavyweight)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Extra Heavy-
weight)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-182 Regi Assist Start Timing Adjustment
(Tray2/63[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-183 Regi Assist Start Timing Adjustment
(Tray2/126[mm/s]/Labels1)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/126[mm/s]/Labels1)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-184 Regi Assist Start Timing Adjustment
(Tray2/63[mm/s]/Labels2)
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Tray2/63[mm/s]/Labels2)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-185 Regi Assist Start Timing Adjustment
(Duplex/126[mm/s]/Plain);
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Duplex/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-186 Regi Assist Start Timing Adjustment
(Duplex/63[mm/s]/Heavyweight);
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Duplex/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-187 Regi Assist Start Timing Adjustment
(Duplex/126[mm/s]/Heavyweight);
0 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Duplex/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-188 Regi Assist Start Timing Adjustment
(Invert/126[mm/s]/Plain)
-18 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Invert/126[mm/s]/Plain)_1[mm/step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-189 Regi Assist Start Timing Adjustment
(Invert/63[mm/s]/Heavyweight1)
28 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Invert/63[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
742-190 Regi Assist Start Timing Adjustment
(Invert/126[mm/s]/Heavyweight1)
-18 -127 127 Adjusts the Assist Operation start timing when Regi is ejected (Invert/126[mm/s]/Heavyweight)_1[mm/
step]
**Adjusting the value in the plus (+) direction delays the Assist Operation Start timing.
OO
Table 1 NVM 742_Paper Handling List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description
Write
Allowed/
Protected
Can be
initialized