05/2014
6-50
DC SC2020
6.3.6 NVM 742_Paper Handling List
Version 1.1
General
742-191 Regi Assist Stop Timing Adjustment
(Tray1/MSI Common)
0 0 961 Adjusts the timing of Regi Feed start to stop (Tray1/Common MSI)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
OO
742-192 Regi Assist Stop Timing Adjustment
(MSI)
0 0 961 Adjusts the timing of Regi Feed start to stop (MSI)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
OO
742-193 Regi Assist Stop Timing Adjustment
(1G)
0 0 961 Adjusts the timing of Regi Feed start to stop (1G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
OO
742-194 Regi Assist Stop Timing Adjustment
(2G)
0 0 961 Adjusts the timing of Regi Feed start to stop (2G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
OO
742-195 Regi Assist Stop Timing Adjustment
(3G)
0 0 961 Adjusts the timing of Regi Feed start to stop (3G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
OO
742-196 Regi Assist Stop Timing Adjustment
(4G)
0 0 961 Adjusts the timing of Regi Feed start to stop (4G)_1[ms/step]
*Adjusting the value in the plus (+) direction delays the Stop timing.
OO
742-197 Regi Assist Stop Timing Adjustment
(Tray 1/126[mm/s]/Plain);
0 0 395 Adjusts the timing of when the Tray1 Feed CL should stop after the Regi Feed starts (Tray1/126[mm/s]/
Plain)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the Tray1 Feed CLL OFF timing.
OO
742-198 Regi Assist Stop Timing Adjustment
(MSI/126[mm/s]/Plain)
0 0 526 Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Plain)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
OO
742-199 Regi Assist Stop Timing Adjustment
(MSI/63[mm/s]/Heavyweight)
0 0 961 Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Heavyweight1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
OO
742-200 Regi Assist Stop Timing Adjustment
(MSI/126[mm/s]/Heavyweight)
0 0 526 Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Heavyweight1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
OO
742-201 Regi Assist Stop Timing Adjustment
(MSI/63[mm/s]/Extra Heavyweight)
0 0 961 Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/63[mm/s]/
Extra Heavyweight)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
OO
742-202 Regi Assist Stop Timing Adjustment
(MSI/63[mm/s]/Labels1)
0 0 961 Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Labels1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
OO
742-203 Regi Assist Stop Timing Adjustment
(MSI/126[mm/s]/Labels1)
0 0 526 Adjusts the timing of when the MSI Feed CL should stop after the Regi Feed starts (MSI/126[mm/s]/
Labels1)
Adjusts by 1[ms/step].
*Adjusting the value in the plus (+) direction delays the MSI Feed CLL OFF timing.
OO
Table 1 NVM 742_Paper Handling List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description
Write
Allowed/
Protected
Can be
initialized