Remote control commands
R&S
®
RTP
2008User Manual 1337.9952.02 ─ 12
TRIGger<m>:USB:SCONdition......................................................................................2014
TRIGger<m>:USB:SMIN...............................................................................................2015
TRIGger<m>:USB:SMAX..............................................................................................2015
TRIGger<m>:USB:SPEC.............................................................................................. 2015
TRIGger<m>:USB:STCO..............................................................................................2015
TRIGger<m>:USB:TCONdition......................................................................................2016
TRIGger<m>:USB:TMIN...............................................................................................2016
TRIGger<m>:USB:TMAX..............................................................................................2016
TRIGger<m>:USB:TOKen.............................................................................................2016
TRIGger<m>:USB:WADD............................................................................................. 2017
TRIGger<m>:USB:WEND.............................................................................................2017
TRIGger<m>:USB:WETCheck.......................................................................................2017
TRIGger<m>:USB:WFRN............................................................................................. 2017
TRIGger<m>:USB:WPAY..............................................................................................2017
TRIGger<m>:USB:WPID.............................................................................................. 2018
TRIGger<m>:USB:WPOR.............................................................................................2018
TRIGger<m>:USB:WSEU............................................................................................. 2018
TRIGger<m>:USB:WSTC............................................................................................. 2018
TRIGger<m>:USB:TYPE <Type>
Selects the trigger type for USB analysis. The available trigger types depend on the
activated USB protocol type.
Parameters:
<Type> SOP | EOP | RST | SUSPend | RESume | TOKen | DATA |
HANDshake | SPECial | ERRCond
SOP
Sets the trigger to the SOP (start of packet) field. The start of
packet condition is the end of the SYNC field. The trigger instant
is the end of the SOP field.
EOP
Sets the trigger to the EOP (end of packet) field. Not available
for USB High Speed and USB HSIC protocol types. The trigger
instant is the beginning of the EOP field.
RST
Sets the trigger to the Reset field. Not available for USB High
Speed and USB HSIC protocol types. For more information on
the reset condition, see the USB standard. The trigger instant is
the end of the 10 ms period after the SE0 field.
SUSPend
Sets the trigger to the Suspend field. Not available for USB High
Speed and USB HSIC protocol types. For more information on
the suspend condition, see the USB standard. The trigger
instant will be declared after the defined 3 ms timeout.
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz RTP Series and is the answer not in the manual?

Rohde & Schwarz RTP Series Specifications

General IconGeneral
BrandRohde & Schwarz
ModelRTP Series
CategoryTest Equipment
LanguageEnglish

Related product manuals