Remote Control Commands
R&S
®
SMBV100B
637User Manual 1178.4460.02 ─ 03
Parameters:
<ButtonBrightnes> integer
Range: 1 to 20
*RST: n.a. (no preset. default: 14)
Example:
DISPlay:BUTTon:BRIGhtness 15
Manual operation: See "RF Hardkey" on page 511
:DISPlay:UPDate <Update>
Activates the refresh mode of the display.
Parameters:
<Update> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 1)
Example: See Example "Activating screen saver mode and display
update" on page 635
Manual operation: See "Display Update is" on page 512
:DISPlay:ANNotation:AMPLitude <State>
Indicates asterisks instead of the level values in the status bar.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 1)
Example: See Example "Activating screen saver mode and display
update" on page 635
Manual operation: See "Annotation Amplitude" on page 541
:DISPlay:ANNotation:FREQuency <State>
Indicates asterisks instead of the frequency values in the status bar.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 1)
Example: See Example "Activating screen saver mode and display
update" on page 635
Manual operation: See "Annotation Frequency" on page 541
:DISPlay:ANNotation[:ALL] <State>
Displays asterisks instead of the level and frequency values in the status bar of the
instrument.
DISPlay Subsystem