5.3.2 Forming DC link capacitors
Overview
You have to reform the DC link capacitors if the converter has been stored for more than one
year. Non-formed DC link capacitors can damage the converter in operation.
Precondition
The converter has not yet been used, and according to the production date it was made over
a year ago.
The production date of the converter is coded in the 3rd and 4th digit of the serial number on the
rating plate: S . . ③④…
● Example: Serial number S ZVK5375000118 → Production date May 2018
Table 5-1 Production year and month
Digit ③ Production year Digit ④ Month of manufacture
K 2018 1 ... 9 January ... September
L 2019 0 October
M 2020 N November
… … D December
Function description
You form the DC link capacitors by supplying the converter with a line voltage of ≤ 100% of the
rated voltage for a defined time.
)RUPLQJIRUVWRUDJHWLPHVRI\HDUV
)RUPLQJIRUVWRUDJHWLPHVRI\HDUV
)RUPLQJIRUVWRUDJHWLPHVRIDQGPRUH\HDUV
8>@
W>K@
Figure 5-3 Forming the DC link capacitors
Commissioning
5.3 Preparing for commissioning
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB 107