EasyManua.ls Logo

Siemens SINAMICS G120XA - Motor Brakes with and Without Active Compound Braking

Siemens SINAMICS G120XA
918 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.6.4.2 Compound braking
Function description
:LWKFRPSRXQGEUDNLQJ
$GGLWLYH'&
:LWKRXWFRPSRXQGEUDNLQJ
6SHHG
0RWRUFXUUHQW
'&OLQNYROWDJH
U
W
W
W
W
W
W
Figure 6-68 Motor brakes with and without active compound braking
Compound braking prevents the DC-link voltage increasing above a critical value. The
converter activates compound braking depending on the DC-link voltage. Above a DC-link
voltage threshold (r1282), the converter adds a DC current to the motor current. The DC current
brakes the motor and prevents an excessive increase in the DC-link voltage.
Note
Compound braking is possible only with the U/f control.
Compound braking does not operate in the following cases:
The "flying restart" function is active
DC braking is active
Vector control is selected
NOTICE
Overheating of the motor due to compound braking
The motor will overheat if you use compound braking too frequently or for too long. This may
damage the motor.
Monitor the motor temperature.
Allow the motor to adequately cool down between braking operations.
If necessary, select another motor braking method.
Advanced commissioning
6.6 Motor control
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB 299

Table of Contents

Related product manuals