Rated motor voltage
Rated motor current
Rated motor power
Rated motor frequency
Rated motor speed
Motor cooling:
SELF: Natural cooling
FORCED: Forced-air cooling
LIQUID: Liquid cooling
NO FAN: Without fan
Select the appropriate application:
VEC STD: In all applications, which do not fit the other setting options.
PUMP FAN: Applications involving pumps and fans
SLVC 0HZ: Applications with short ramp-up and ramp-down times.
PUMP 0HZ: Applications involving pumps and fans with optimized efficiency. The setting
only makes sense for steady-state operation with slow speed changes. We recommend
setting VEC STD if load surges in operation cannot be ruled out.
V LOAD: Applications with high breakaway torque
Select the control mode:
VF LIN: U/f control with linear characteristic
VF LIN F: Flux current control (FCC)
VF QUAD: U/f control with square-law characteristic
SPD N EN: Sensorless vector control
3
02792/7
3
027&855
3
02732:
3
027)5(4
3
027530
3
027&22/
3
7(&$33/
3
&75/02'
Commissioning
5.4 Quick commissioning using the BOP-2 operator panel
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB 119