EasyManua.ls Logo

Siemens SINAMICS G120XA - Replacing the Fuse for the External Fan; Required Tools

Siemens SINAMICS G120XA
918 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Disconnect the wires.
[PP
[PP
4. Remove the power supply.
The power supply is removed.
Installing the power supply
1. Mount the power supply on the top hat rail.
2. Connect the wires.
3. Install the front cover.
4. Insert 2 screws (torx 25) of the front cover.
Tightneing torque: 3 Nm.
The power supply board is installed.
10.2.4.5 Replacing the fuse for the external fan
Precondition
The converter power supply is switched off.
Required tools
Torque wrench for TX-20 screws
Torque wrench for TX-25 screws
Slot screwdriver 0.6 mm × 3.5 mm
Corrective maintenance
10.2 Replacing spare parts
SINAMICS G120XA converter
850 Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB

Table of Contents

Related product manuals