EasyManua.ls Logo

Siemens SINAMICS G120XA - BO: Profidrive PZD1 Receive Bit-Serial; PZD1 Recv Bitw; BO: Profidrive PZD2 Receive Bit-Serial; PZD2 Recv Bitw

Siemens SINAMICS G120XA
918 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Bit 12 ON OFF -
13 Bit 13 ON OFF -
14 Bit 14 ON OFF -
15 Bit 15 ON OFF -
Dependency: See also: p2051, p2080, p2081, p2082, p2083
Note
r2089 together with p2080 to p2084 forms five binector-connector converters.
r2090.0...15 BO: PROFIdrive PZD1 receive bit-serial / PZD1 recv bitw
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2468, 9204,
9206, 9360
Min:
-
Max:
-
Factory setting:
-
Description: Binector output for bit-serial interconnection of PZD1 (normally control word 1) received from the PROFIdrive
controller.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 ON OFF -
01 Bit 1 ON OFF -
02 Bit 2 ON OFF -
03 Bit 3 ON OFF -
04 Bit 4 ON OFF -
05 Bit 5 ON OFF -
06 Bit 6 ON OFF -
07 Bit 7 ON OFF -
08 Bit 8 ON OFF -
09 Bit 9 ON OFF -
10 Bit 10 ON OFF -
11 Bit 11 ON OFF -
12 Bit 12 ON OFF -
13 Bit 13 ON OFF -
14 Bit 14 ON OFF -
15 Bit 15 ON OFF -
r2091.0...15 BO: PROFIdrive PZD2 receive bit-serial / PZD2 recv bitw
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2468, 9204,
9206
Min:
-
Max:
-
Factory setting:
-
Description: Binector output for bit-serial interconnection of PZD2 received from the PROFIdrive controller.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 ON OFF -
01 Bit 1 ON OFF -
02 Bit 2 ON OFF -
03 Bit 3 ON OFF -
04 Bit 4 ON OFF -
Parameters
7.3 Parameters
SINAMICS G120XA converter
572 Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB