p29651[0...n] BI: ON/OFF1 (OFF1) / ON/OFF1 (OFF1)
Access level: 3 Calculated: - Data type: Unsigned32 / Binary
Can be changed: T Scaling: - Dynamic index: CDS, p0170
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
0
Description: Sets the signal source for the command "ON/OFF1 (OFF1)".
p29652[0...n] BI: ON/OFF2 (OFF2) / ON/OFF2 (OFF2)
Access level: 3 Calculated: - Data type: Unsigned32 / Binary
Can be changed: T Scaling: - Dynamic index: CDS, p0170
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
722.0
Description: Sets the signal source for the command "ON/OFF2 (OFF2)".
r29659 CO/BO: Status word:command / Cmd stat
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Command status is for ON/OFF1, OFF2 which can connect to p0840, p0844.
Parameters
7.3 Parameters
SINAMICS G120XA converter
722 Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB