01P
Mounting the shield connection kit for the Power Module, FSA ... FSC
Procedure
1. Remove the two screws and two U clamps from the bottom of the converter .
2. Mount the two U clamps with the two screws on the shield plate .
3. Fasten the shield plate in place using two screws .
1P
You have now mounted the shield connection kit.
Mounting the shield connection kit for the Power Module, FSD ... FSG
Note
For converters FSD to FSG, the shield connection kit for the Power Module is not included in
the scope of delivery of the converter and only available optionally.