Table 3-2 FSH and FSJ
Drill pattern Dimensions FSH FSJ
A1 150 247
A2 150 200
A3 150 200
A4 225 367
A5 225 315
B 1444 1399
G1 49 61
G2 49 60
Ø 20 20
Fixings (bolts, wash‐
ers, nuts)
7 × M8 7 × M8
Tightening torque (Nm) 25 25
3.3.3 Mounting the shield connection kit
Overview
We recommend that you mount the shield connection kits provided. The shield connection kit
makes it simpler to install the converter in compliance with EMC regulations and to provide
strength relief for the connected cables.
Mounting the shield connection kit for the Control Unit
Note
The shield connection kit for the Control Unit is available for converters FSD to FSG only.
Attach the shielding plate to the bottom of the Control Unit, and use a cross-tip screwdriver to
tighten the screw to fix it onto the converter.
Mounting
3.3 Mounting the converter
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB 49