A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2207[0...n] CO: Technology controller fixed value 7 / Tec_ctr fix val 7
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: PERCENT Dynamic index: DDS, p0180
Unit group: 9_1 Unit selection: p0595 Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
70.00 [%]
Description: Sets the value for fixed value 7 of the technology controller.
Dependency: See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2208[0...n] CO: Technology controller fixed value 8 / Tec_ctr fix val 8
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: PERCENT Dynamic index: DDS, p0180
Unit group: 9_1 Unit selection: p0595 Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
80.00 [%]
Description: Sets the value for fixed value 8 of the technology controller.
Dependency: See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2209[0...n] CO: Technology controller fixed value 9 / Tec_ctr fix val 9
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: PERCENT Dynamic index: DDS, p0180
Unit group: 9_1 Unit selection: p0595 Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
90.00 [%]
Description: Sets the value for fixed value 9 of the technology controller.
Dependency: See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2210[0...n] CO: Technology controller fixed value 10 / Tec_ctr fix val 10
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: PERCENT Dynamic index: DDS, p0180
Unit group: 9_1 Unit selection: p0595 Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
100.00 [%]
Description: Sets the value for fixed value 10 of the technology controller.
Dependency: See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.