Selecting the number of drive data sets
Parameter p0180 defines the number of drive data sets (1 ... 4).
Parameter Description
p0010 = 0 Drive commissioning: Ready
p0010 = 15 Drive commissioning: Data sets
p0180 Drive data set (DDS) number
Copying the drive data sets
Parameter Description
p0819[0] Source drive data set
p0819[1] Target drive data set
p0819[2] = 1 Starts the copy operation
Parameters
Number Name Factory setting
p0010 Drive commissioning parameter filter 1
r0051 CO/BO: Drive data set DDS effective -
p0180 Drive data set (DDS) number 1
p0819[0 … 2] Copy drive data set DDS 0
p0820[C] BI: Drive data set DDS selection, bit 0 0
p0821[C] BI: Drive data set DDS selection, bit 1 0
p0826[M] Motor changeover, motor number 0
Advanced commissioning
6.10 Switchover between different settings
SINAMICS G120XA converter