10.2.3.4 Replacing the internal fan, FSH/FSJ only
Preconditions
The converter power supply is switched off.
Required tools
Torque wrench for TX-25 screws
Function description
Removing the fan
1. Remove 2 screws (TX-25) of the front cover.
7;
7;
1P
2. Remove the front cover.
3. Remove the connector of the fan cable.
Corrective maintenance
10.2 Replacing spare parts
SINAMICS G120XA converter
838 Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB