CO Connector output
CO/BO Connector/binector output
Interconnecting signals in the converter (Page 882)
Can be changed
"-" The parameter can be changed in any state, and the change becomes imme‐
diately effective.
C(x) The parameter can only be changed for the following settings:
C: p0010 > 0
C(x): p0010 = x
U The motor is switched on
T The motor is switched off and p0010 = 0
Unit group and unit selection
For parameters where the unit can be switched over.
"Unit group": to which group does the parameter belong?
"Unit selection": with which parameter do you switch over the unit?
Data type
● Integer8 I8 8-bit integer
● Integer16 I16 16-bit integer
● Integer32 I32 32-bit integer
● Unsigned8 U8 8-bit without sign
● Unsigned16 U16 16-bit without sign
● Unsigned32 U32 32-bit without sign
● FloatingPoint32 Float 32-bit floating-point number
Scaling
Specification of the reference variable with which a signal value is automatically converted with
a BICO interconnection.
The following reference variables are available:
● p2000 … p2003: Reference speed, reference voltage, etc.
● PERCENT: 1.0 = 100%
● 4000H: 4000 hex = 100 % (word) or 4000 0000 hex = 100 % (double word)
More information
Firmware version: V1.00
Firmware version of the basic system V04712502_1000100
Parameters
7.2 Explanation of the detailed parameter list
SINAMICS G120XA converter