EasyManua.ls Logo

Siemens SINAMICS G120XA - Options for Electrical Cabinets; Opt Elec Cabinet; Power Unit EEPROM Characteristics; PU Characteristics; Service Parameter; Serv Par

Siemens SINAMICS G120XA
918 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Calculate speed actual value smoothing time Yes No -
Dependency: See also: r3925
Note
The parameter is a copy of p1959.
r3930[0...4] Power unit EEPROM characteristics / PU characteristics
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Displays the characteristics (A5E number and versions) of the power unit.
[0]: A5E number xxxx (A5Exxxxyyyy)
[1]: A5E number yyyy (A5Exxxxyyyy)
[2]: File version (logistic)
[3]: File version (fixed data)
[4]: File version (calib data)
p3931 Options for electrical cabinets / Opt elec cabinet
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
0000 0000 0000 0000 bin
Description: Sets the options for the Power Module 330 (PM330).
Bit field: Bit Signal name 1 signal 0 signal FP
00 Line filter Yes No -
01 Line Harmonics Filter Yes No -
02 du/dt filter compact Voltage Peak Limiter Yes No -
03 Motor reactor Yes No -
04 du/dt filter plus Voltage Peak Limiter Yes No -
05 w/o line reactor Yes No -
07 EmergOff button Yes No -
08 Emergency Stop category 0 Yes No -
09 Emergency Stop category 1 Yes No -
10 Emergency Stop category 1 24 V Yes No -
11 Braking Module (25 kW) Yes No -
12 Braking Module (50 kW) Yes No -
p3950 Service parameter / Serv par
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C1, T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: For service personnel only.
Parameters
7.3 Parameters
SINAMICS G120XA converter
658 Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB

Table of Contents

Related product manuals