Dependency: See also: p2021
NOTICE
The display is updated after switching on, and not cyclically.
r2060[0...10] CO: PROFIdrive PZD receive double word / PZD recv DW
Access level: 3 Calculated: - Data type: Integer32
Can be changed: - Scaling: 4000H Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2440, 2468
Min:
-
Max:
-
Factory setting:
-
Description: Connector output to interconnect PZD (setpoints) with double word format received from the fieldbus controller.
Index: [0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 + 10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
Dependency: See also: r2050
NOTICE
Where there is a multiple interconnection of a connector output, all the connector inputs must either have Integer or
FloatingPoint data types.
A BICO interconnection for a single PZD can only take place either on r2050 or r2060.
p2061[0...15] CI: PROFIdrive PZD send double word / PZD send DW
Access level: 3 Calculated: - Data type: Unsigned32 /
Integer32
Can be changed: T, U Scaling: 4000H Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2470
Min:
-
Max:
-
Factory setting:
0
Description: Selects the PZD (actual values) with double word format to be sent to the fieldbus controller.
Parameters
7.3 Parameters
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB 565