6.4.1.4 Fixed speed setpoint as setpoint source
Function description
)L[HGVSHHGVHWSRLQW
6HOHFWLRQ
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
DFWLYH
0DLQVHWSRLQW
6FDOLQJ
6FDOLQJ
6XSSOHPHQWDU\VHWSRLQW
S
S
S
U
U
S
U
Figure 6-32 Fixed speed setpoint as setpoint source
The converter makes a distinction between two methods when selecting the fixed speed
setpoints:
Directly selecting a fixed speed setpoint
)L[HGVHWSRLQWVHOHFWLRQELW
)L[HGVHWSRLQWVHOHFWLRQELW
)L[HGVHWSRLQWVHOHFWLRQELW
)L[HGVHWSRLQWVHOHFWLRQELW
)L[HGVHWSRLQW
)L[HGVHWSRLQW
)L[HGVHWSRLQW
)L[HGVSHHGVHWSRLQW
HIIHFWLYH
)L[HGVHWSRLQW
U
S
S
S
S
S
S
S
S
Figure 6-33 Direct selection of the fixed speed setpoint
Table 6-45 Resulting setpoint
p1020 p1021 p1022 p1023 Resulting setpoint
0 0 0 0 0
1 0 0 0 p1001
0 1 0 0 p1002
1 1 0 0 p1001 + p1002
0 0 1 0 p1003
1 0 1 0 p1001 + p1003
0 1 1 0 p1002 + p1003
1 1 1 0 p1001 + p1002 + p1003
0 0 0 1 p1004
1 0 0 1 p1001 + p1004
Advanced commissioning
6.4 Setpoints and setpoint processing
SINAMICS G120XA converter