02 Fixed setpoint bit 2 Yes No -
03 Fixed setpoint bit 3 Yes No -
04 DDS selection bit 0 Yes No -
05 DDS selection bit 1 Yes No -
08 Technology controller enable Yes No -
11 Reserved - - -
12 Reserved - - -
13 External fault 1 (F07860) No Yes -
15 CDS bit 1 Yes No -
Note
CDS: Command Data Set
DDS: Drive Data Set
The following control bits are displayed in r0055:
Bit 00: r1198.0
Bit 01: r1198.1
Bit 02: r1198.2
Bit 03: r1198.3
Bit 04: r0837.0
Bit 05: r0837.1
Bit 08: r2349.0 (negated)
Bit 13: r2138.13 (negated)
Bit 15: r0836.1
r0055.0...15 CO/BO: Supplementary control word / Suppl STW
CUG120XA_USS (DC
braking)
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2513
Min:
-
Max:
-
Factory setting:
-
Description: Display and BICO output for supplementary control word.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fixed setpoint bit 0 Yes No -
01 Fixed setpoint bit 1 Yes No -
02 Fixed setpoint bit 2 Yes No -
03 Fixed setpoint bit 3 Yes No -
04 DDS selection bit 0 Yes No -
05 DDS selection bit 1 Yes No -
08 Technology controller enable Yes No -
09 DC braking enable Yes No -
11 Reserved - - -
12 Reserved - - -
13 External fault 1 (F07860) No Yes -
15 CDS bit 1 Yes No -
Parameters
7.3 Parameters
SINAMICS G120XA converter
368 Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB