General-purpose timer (TIM2) RM0453
824/1450 RM0453 Rev 5
26.3 TIM2 functional description
26.3.1 Time-base unit
The main block of the programmable timer is a 32-bit counter with its related auto-reload
register. The counter can count up, down or both up and down but also down or both up and
down. The counter clock can be divided by a prescaler.
The counter, the auto-reload register and the prescaler register can be written or read by
software. This is true even when the counter is running.
The time-base unit includes:
Counter Register (TIMx_CNT)
Prescaler Register (TIMx_PSC)
Auto-Reload Register (TIMx_ARR)
The auto-reload register is preloaded. Writing to or reading from the auto-reload register
accesses the preload register. The content of the preload register are transferred into the
shadow register permanently or at each update event (UEV), depending on the auto-reload
preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter
reaches the overflow (or underflow when downcounting) and if the UDIS bit equals 0 in the
TIMx_CR1 register. It can also be generated by software. The generation of the update
event is described in detail for each configuration.
The counter is clocked by the prescaler output CK_CNT, which is enabled only when the
counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller
description to get more details on counter enabling).
Note that the actual counter enable signal CNT_EN is set 1 clock cycle after CEN.
Prescaler description
The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It
is based on a 16-bit counter controlled through a 16-bit/32-bit register (in the TIMx_PSC
register). It can be changed on the fly as this control register is buffered. The new prescaler
ratio is taken into account at the next update event.
Figure 189 and Figure 190 give some examples of the counter behavior when the prescaler
ratio is changed on the fly:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STMicroelectronics STM32WL5 Series and is the answer not in the manual?

STMicroelectronics STM32WL5 Series Specifications

General IconGeneral
BrandSTMicroelectronics
ModelSTM32WL5 Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals