Model 2601B-PULSE System SourceMeter Instrument Reference Manual Section 11: TSP command reference
2601B-PULSE-901-01A April 2020 11-21
Example
bufferCapacity = smua.nvbuffer1.capacity
print(bufferCapacity)
Reads the capacity of dedicated reading
buffer 1 (source-measure unit (SMU)
channel A).
Output:
1.49789e+05
The above output indicates that the buffer
can hold 149789 readings.
Also see
Reading buffers (on page 5-1)
smua.makebuffer() (on page 11-193)
smua.measure.overlappedY() (on page 11-205)
smua.measure.Y() (on page 11-209)
smua.nvbufferY (on page 11-211)
smua.trigger.measure.Y() (on page 11-251)
bufferVar.clear()
This function empties the buffer.
Usage
bufferVar.clear()
The reading buffer; can be a dynamically allocated user-defined buffer or a dedicated
reading buffer
Details
This function clears all readings and related recall attributes from the buffer (for example,
bufferVar.timestamps and bufferVar.statuses) from the specified buffer.
Example
Clears dedicated reading buffer 1
(source-measure unit (SMU) channel A).
Also see
Reading buffers (on page 5-1)
smua.nvbufferY (on page 11-211)