In this section:
Command summary ............................................................... 14-1
Script command equivalents .................................................. 14-2
Command reference .............................................................. 14-3
Command summary
The IEEE Std 488.2 common commands that are supported by the 2601B-PULSE are summarized in
the following table. Although commands are shown in uppercase, common commands are not case
sensitive, and either uppercase or lowercase can be used. Note that although these commands are
essentially the same as those defined by the IEEE Std 488.2 standard, the 2601B-PULSE does not
strictly conform to that standard.
Unlike other commands, like those listed in TSP commands (on page 11-8), each common
command must be sent in a separate message.
The common commands cannot be used in scripts.
Command
Name
Description
*CLS
Clear status
Clears all event registers and Error Queue. For detailed
information including status commands, see the Status model
(on page 15-1).
*ESE mask
Event enable command
Program the Standard Event Status Enable Register. For
detailed information including status commands, see the
Status model (on page 15-1).
*ESE?
Event enable query
Read the Standard Event Status Enable Register. For
detailed information including status commands, see the
Status model (on page 15-1).
*ESR?
Event status register query
Read/clear the Standard Event Enable Register. For detailed
information including status commands, see the Status model
(on page 15-1).
*IDN?
Identification query
Returns the manufacturer, model number, serial number, and
firmware revision levels of the unit. For detailed information,
see Identification query: *IDN? (on page 14-3).
*OPC
Operation complete
command
Set the Operation Complete bit in the Standard Event
Register after all pending commands, including overlapped
commands, have completed. For detailed information, see
Operation complete and query: *OPC and *OPC? (on page
14-3).
Section 14
Common commands

Table of Contents

Other manuals for Tektronix Keithley 2601B-PULSE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix Keithley 2601B-PULSE and is the answer not in the manual?

Tektronix Keithley 2601B-PULSE Specifications

General IconGeneral
BrandTektronix
ModelKeithley 2601B-PULSE
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals