2-36 Phaser 6128MFP Service Manual
Theory of Operation
1. The ADC Sensor reads the patch density.
2. The amount of registration shift is calculated from the threshold value
determined in step 1 and the patch density measured in step 3.
3. The Laser Unit write timing is changed according to the amount of
registration shift.
Fuser Control
Fuser Temperature Control
After the target temperature is set, the Heat Roller surface temperature is
controlled by turning the Heater Lamp On/Off.
Temperature of individual area of the Heat Roller is detected by the Fuser Non-
Contact Sensor (NCS) in the middle of the Heat Roller and the Temp Sensor at the
edge of it.
The target temperature set up varies depending on the time of Warm-up, Printing,
or Process Control. The target set temperature is changed based on the printer’s
interior temperature detected by the Humidity Sensor.
Cool Down
As printing continues, the distribution of temperature in the Heat Roller becomes
uneven in both the paper feed and non-paper feed areas. Cooling Down suspends
paper feeling for a certain period of time so that the Heat Roller temperature
distribution can be uniform.
When the temperature of the Heat Roller edge is high, cooling down is performed
to lower the temperature to the target value.