Service Parts Disassembly
4. Release 3 hooks that secure the Registration Sensor to the Feeder Assembly 
and remove the sensor.
5. Disconnect P/J232 from the Registration Sensor.
Registration Roller
PL3.2.9
1. Remove the Upper Frame Assembly (page 8-68).
The Registration Actuator Out is spring-loaded by a small spring located 
under the actuator.
2. Release the hook on the Registration Actuator Out and shift the Registration 
Roller Actuator to the right side.