Interfaces WideArea Networks(WANs)
IX20 User Guide
114
l
Set the amount of time that the interfaceis down before the test can be
considered to havefailed.
(config network interface my_wan surelink tests 1)>
interface_down_time value
(config network interface my_wan surelink tests 1)>
where value is any number of weeks, days, hours, minutes, or seconds, and
takes the format number{w|d|h|m|s}.
For example, to set interface_down_time to ten minutes, enter either 10m or
600s:
(config network interface my_wan surelink tests 1)>
interface_down_time 600s
(config)>
l
Set the amount of time to wait for the interfaceto connect for the first time
before the test isconsidered to have failed.
(config network interface my_wan surelink tests 1)>
interface_timeout value
(config network interface my_wan surelink tests 1)>
where value is any number of weeks, days, hours, minutes, or seconds, and
takes the format number{w|d|h|m|s}.
For example, to set interface_timeout to ten minutes, enter either 10m or
600s:
(config network interface my_wan surelink tests 1)>
interface_timeout 600s
(config)>
n
custom_test: Tests the interface with custom commands.
If custom_test is set, set the commands to run to perform the test:
(config network interface my_wan surelink tests 1)> custom_
test_commands "string"
(config network interface my_wan surelink tests 1)>
n
tcp_connection: Teststhat the interface can reach a destination port on the
configured host.
If tcp_connection is selected, complete the following:
l
Set the hostname or IPaddress of the host to create a TCP connection to:
(config network interface my_wan surelink tests 1)> tcp_host
hostname/IP_address
(config network interface my_wan surelink tests 1)>