Serial port ConfigureModbusmode
IX20 User Guide
291
l
Asingle IPaddress or host name.
l
Anetwork designation in CIDRnotation, for example, 2001:db8::/48.
l
any: No limit to IPv6 addresses that can access the service-type.
iv. Click again to list additional IPaddressesor networks.
n
To limit access to hosts connected through a specified interface on the IX20 device:
i. Click Interfaces.
ii. For Add Interface, click .
iii. For Interface, select the appropriate interface from the dropdown.
iv. Click again to allow access through additional interfaces.
n
To limit access based on firewall zones:
i. Click Zones.
ii. For Add Zone, click .
iii. For Zone, select the appropriate firewall zonefrom the dropdown.
See Firewall configuration for information about firewall zones.
iv. Click again to allow access through additional firewall zones.
d. Toggle on Enable mDNSto enable Multicast DNS(mDNS) reporting for thisservice. This
feature is disabled by default.
19. Expand Logging Settingsto configure logging for thisserial port.
a. To enable logging, click to toggle on Enable.
b. In the Log file name field, enter a descriptivename for the log file.
c. For Log file size, typethe size of the log file. When the log file reachesthe size limit, the
current file issaved and anew file is created. The default is 65536 bytes.
d. From the Type of data to log list box, specify the type of data that should be saved.
n
Received
n
Transmitted
n
Both
n
Both with arrows. This is the default.
e. If you want to log the time at which date wasreceived or transmitted, click the
Timestampstoggle to Enable.
f. If you want to log the data as hexadecimal values, click the Hexadecimal toggle to
Enable.
Note You can review the message log in the Serial Port Log page. See Review the serial
port message log.
20. Click Apply to save the configuration and apply the change.
Configure Modbusmode
Modbusmode allowsyou to use the serial port for Modbus. See Modbusgateway.
To change the configuration to match the serial configuration of the device to which you want to
connect:
Web

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX20 and is the answer not in the manual?

Digi IX20 Specifications

General IconGeneral
CategoryWireless Router
Cellular Connectivity4G LTE
Ethernet Ports4
Wi-Fi802.11ac
SIM Slots2
WAN Ports1
LAN Ports3
Weight0.5 kg
Operating Temperature-40°C to +70°C (-40°F to +158°F)