Wi-Fi Configurean open Wi-Fi accesspoint
IX20 User Guide
326
The accesspoint must be assigned to an active LAN, or a bridge that is assigned to an active
LAN.
2. Save the configuration and apply the change
(config)> save
Configuration saved.
>
3. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Edit an existing Access point
1. Select the device in Remote Manager and click Actions> Open Console, or log into the IX20
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to accessthe Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Show available access points:
(config)> network wifi ap ?
Additional Configuration
------------------------------------------------------------------------
-------
digi_ap Digi AP
(config)>
4. Set the SSIDfor the appropriate access point:
(config)> network wifi ap digi_ap ssid my_SSID
(config)>
5. SSIDbroadcasting is enabled by default for the preconfigured access points. If SSID
broadcasting is disabled:
(config)> network wifi ap digi_ap ssid_broadcast true
(config)>
6. Set the security for the accesspoint to an open security method:
(config network wifi ap new_AP)> encryption type value
(config network wifi ap new_AP)>
where value is either:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX20 and is the answer not in the manual?

Digi IX20 Specifications

General IconGeneral
CategoryWireless Router
Cellular Connectivity4G LTE
Ethernet Ports4
Wi-Fi802.11ac
SIM Slots2
WAN Ports1
LAN Ports3
Weight0.5 kg
Operating Temperature-40°C to +70°C (-40°F to +158°F)