User authentication Local users
IX20 User Guide
887
Note Every user must be configured with at least one group. You can add multiple groupsto a
user by clicking Add again and selecting the next group.
9. (Optional) Add SSH keys for the user to use passwordlessSSH login:
a. Click SSH keys.
b. In Add SSH key, paste or type a public encryption key that this user can use for
passwordlessSSH login and click .
10. (Optional) Configure two-factor authentication for SSH, telnet, and serial console login:
a. Click Two-factor authentication.
b. Check Enable to enable two-factor authentication for this user.
c. Select the Verification type:
n
Time-based (TOTP): Time-based One-Time Password (TOTP) authentication uses
the current time to generate a one-time password.
n
Counter-based (HOTP): HMAC-based One-Time Password (HOTP) usesa counter to
validate a one-time password.
d. Generate a Secret key:
i. Click ... next to the field label and select Generate secret key.
ii. Copy the secret key for use with an application or mobile device to generate
passcodes.
e. For time-based verification only, select Disallow code reuse to prevent a code from being
used more than once during the time that it is valid.
f. For time-based verification only, in Code refresh interval, type the amount of time that a
code will remain valid.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}. For example, to set Code refresh interval to ten minutes,
enter 10m or 600s.
g. In Valid code window size, type the allowed number of concurrently valid codes. In cases
where TOTPis being used, increasing the Valid code window size may be necessary when
the clocksused by the server and client are not synchronized.
h. For Login limit, type the number of times that the user is allowed to attempt to log in
during the Login limit period. Set Login limit to 0 to allow an unlimited number of login
attempts during the Login limit period.
i. For Login limit period, typethe amount of time that the user is allowed to attempt to log
in.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}. For example, to set Login limit period to ten minutes, enter
10m or 600s.
j. Scratch codes are emergency codes that may be used once, at any time. To add a scratch
code:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX20 and is the answer not in the manual?

Digi IX20 Specifications

General IconGeneral
CategoryWireless Router
Cellular Connectivity4G LTE
Ethernet Ports4
Wi-Fi802.11ac
SIM Slots2
WAN Ports1
LAN Ports3
Weight0.5 kg
Operating Temperature-40°C to +70°C (-40°F to +158°F)