set igmpsnooping maxresponse
D-Series CLI Reference 11-5
Usage
TheIGMPgroupmembershipintervaltimesetsthefrequencyofhostqueryframetransmissions
andmustbegreaterthantheIGMPmaximumresponsetimeasdescribedinsetigmpsnooping
maxresponseonpage 115.
Example
ThisexampleshowshowtosettheIGMPgroupmembershipintervalto250seconds:
D2(su)->set igmpsnooping groupmembershipinterval 250
set igmpsnooping maxresponse
UsethiscommandtoconfiguretheIGMPquerymaximumresponsetimeforthesystem.
Syntax
set igmpsnooping maxresponse time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
ThisvaluemustbelessthantheIGMPmaximumresponsetimedescribedinsetigmpsnooping
groupmembershipintervalonpage 114.
Example
ThisexampleshowshowtosettheIGMPmaximumresponsetimeto100seconds:
D2(su)->set igmpsnooping maxresponse 100
set igmpsnooping mcrtrexpiretime
UsethiscommandtoconfiguretheIGMPmulticastrouterexpirationtimeforthesystem.
Syntax
set igmpsnooping mcrtrexpire time
time SpecifiestheIGMPmaximumqueryresponsetime.Validvaluesare100‐
255seconds.Thedefaultvalueis100seconds.
Thisvalueworkstogetherwiththesetigmpsnooping
groupmembershipintervalcommandtoremoveportsfromanIGMPgrou p
andmustbelesserthanthegroupmembershipintervalvalue.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys D2 D2G124-12P and is the answer not in the manual?

Enterasys D2 D2G124-12P Specifications

General IconGeneral
BrandEnterasys
ModelD2 D2G124-12P
CategoryNetwork Router
LanguageEnglish

Related product manuals