EasyManua.ls Logo

Enterasys D2 D2G124-12P - Commands; Set Inlinepower Threshold; Show Inlinepower

Enterasys D2 D2G124-12P
496 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
show inlinepower
D-Series CLI Reference 2-31
Commands
Thecommandsusedtoreviewandsetsystempowerparametersarelistedbelow.
show inlinepower
Usethiscommandtodisplaysystempower properties.
Syntax
show inlinepower
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaysystempowerproperties:
D2(su)->show inlinepower
Detection Mode : auto
Unit Status Power(W) Consumption(W) Usage(%) Threshold(%) Trap
---- ------ -------- -------------- -------- ------------ ----
1 auto 480 0.00 0.00 80 enable
set inlinepower threshold
Usethiscommandtosetthepowerusagethreshold.
Syntax
set inlinepower threshold usage-threshold
Parameters
For information about... Refer to page...
show inlinepower 2-31
set inlinepower threshold 2-31
set inlinepower trap 2-32
show port inlinepower 2-32
set port inlinepower 2-33
thresholdvalue Specifiesapowerthresholdasapercentageoftotalsystempowerusage.
Validvaluesare11to100.