set spantree lpwindow
6-46 Spanning Tree Configuration
set spantree lpwindow
UsethiscommandtosettheLoopProtecteventwindowvalueinseconds.
Syntax
set spantree lpwindow value
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
TheLoopProtectWindowisatimervalue,inseconds,thatdefinesaperiodduringwhichLoop
Protecteventsarecounted.Thedefaultvalueis180seconds.Ifthetimerissetto0,theevent
counterisnotresetuntiltheLoopProtecteventthresholdisreached.Ifthethreshold
isreached,
thatconstitutesaloopprotectionevent.
Example
ThisexampleshowshowtosettheLoopProtecteventwindowto120seconds:
D2(rw)->set spantree lpwindow 120
show spantree lpwindow
UsethiscommandtodisplaythecurrentLoopProtecteventwindowvalue.
Syntax
show spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectwindowvalue:
D2(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds
value Specifiesthenumberofsecondsthatcomprisetheperiodduringwhich
LoopProtecteventsarecounted.Thedefaulteventwindowis180
seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys D2 D2G124-12P and is the answer not in the manual?

Enterasys D2 D2G124-12P Specifications

General IconGeneral
BrandEnterasys
ModelD2 D2G124-12P
CategoryNetwork Router
LanguageEnglish

Related product manuals