set inlinepower trap
2-32 Basic Configuration
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtosetthepowerthresholdto50:
D2(su)->set inlinepower threshold 50
set inlinepower trap
UsethiscommandtoenableordisablethesendingofanSNMPtrapmessageforaunitwhenever
thestatusofitsportschanges,orwhenevertheunit’spowerusagethresholdiscrossed.Theunit’s
powerusagethresholdmustbesetusingthesetinlinepowerthresholdcommandasdescribedon
page2‐31.
Syntax
set inlinepower trap {disable | enable}
Parameters
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtoenableinlinepowertrapmessaging:
D2(su)->set inlinepower trap enable
show port inlinepower
UsethiscommandtodisplayallportssupportingPoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
Ifnotspecified,informationforallPoEportswillbedisplayed.
Mode
Switchcommand,read‐only.
disable|enable Disablesorenablesinlinepowertrapmessaging.
port‐string (Optional)DisplaysinformationforspecificPoEport(s).