set rmon alarm properties
D-Series CLI Reference 13-9
set rmon alarm properties
Useî ±thisî ±commandî ±toî ±configureî ±anî ±RMONî ±alarmî ±entry,î ±orî ±toî ±createî ±aî ±newî ±alarmî ±entryî ±withî ±anî ±
unusedî ±alarmî ±indexî ±number.î ±
Syntax
set rmon alarm properties index [interval interval] [object object] [type
{absolute | delta}] [startup {rising | falling | either}] [rthresh rthresh]
[fthresh fthresh] [revent revent] [fevent fevent] [owner owner]
Parameters
Status Whether this event entry is enabled (valid) or disabled.
Variable MIB object to be monitored.
Sample Type Whether the monitoring method is an absolute or a delta sampling.
Startup Alarm Whether alarm generated when this entry is first enabled is rising, falling, or either.
Interval Interval in seconds at which RMON will conduct sample monitoring.
Rising Threshold Minimum threshold for causing a rising alarm.
Falling Threshold Maximum threshold for causing a falling alarm.
Rising Event Index Index number of the RMON event to be triggered when the rising threshold is
crossed.
Falling Event Index Index number of the RMON event to be triggered when the falling threshold is
crossed.
Table 13-44 show rmon alarm Output Details (Continued)
Output Field What It Displays...
index Specifiesî ±anî ±indexî ±numberî ±forî ±thisî ±entry.î ±Maximumî ±numberî ±orî ±entriesî ±isî ±
50.î ±Maximumî ±valueî ±isî ±65535.
intervalî ±interval (Optional)î ±Specifiesî ±anî ±intervalî ±(inî ±seconds)î ±forî ±RMONî ±toî ±conductî ±sampleî ±
monitoring.î ±
objectî ±object (Optional)î ±Specifiesî ±aî ±MIBî ±objectî ±toî ±beî ±monitored.
Note: This parameter is not mandatory for executing the command, but
must be specified in order to enable the alarm entry configuration.
typeî ±absoluteî ±|î ±
delta
(Optional)î ±Specifiesî ±theî ±monitoringî ±methodî ±as:î ±samplingî ±theî ±absoluteî ±
valueî ±ofî ±theî ±object,î ±orî ±theî ±differenceî ±(delta)î ±betweenî ±objectî ±samples.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys D2 D2G124-12P and is the answer not in the manual?

Enterasys D2 D2G124-12P Specifications

General IconGeneral
BrandEnterasys
ModelD2 D2G124-12P
CategoryNetwork Router
LanguageEnglish

Related product manuals