EasyManua.ls Logo

Enterasys D2 D2G124-12P

Enterasys D2 D2G124-12P
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set cdp hold-time
D-Series CLI Reference 3-5
set cdp hold-time
UsethiscommandtosettheholdtimevalueforCDPdiscoveryprotocolconfigurationmessages.
Syntax
set cdp hold-time hold-time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetCDPholdtimeto60seconds:
D2(su)->set cdp hold-time 60
clear cdp
UsethiscommandtoresetCDPdiscoveryprotocolsettingstodefaults.
Syntax
clear cdp {[state] [port-state port-string] [interval] [hold-time] [auth-code]}
Parameters
Defaults
Atleastoneoptionalparametermustbeentered.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheCDPstatetoautoenabled:
D2(su)->clear cdp state
holdtime SpecifiestheholdtimevalueforCDPmessagesinseconds.Validvaluesare
from15to600.
state (Optional)ResetstheglobalCDPstatetoauto enabled.
portstateportstring (Optional)Resetstheportstateonspecificport(s)toautoenabled.
interval (Optional)Resetsthemessagefrequencyintervalto60seconds.
holdtime (Optional)Resetstheholdtimevalueto180seconds.
authcode (Optional)Resetstheauthenticationcodeto16
bytesof00(000000
0000000000).

Table of Contents