show port vlan
D-Series CLI Reference 7-7
Commands
show port vlan
UsethiscommandtodisplayportVLANidentifier(PVID)information.PVIDdeterminesthe
VLANtowhichalluntaggedframesreceivedononeormoreportswillbeclassified.
Syntax
show port vlan [port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,portVLANinformationforallportswillbedisplayed.
Mode
Switchcommand,read‐only.
Example
ThisexampleshowshowtodisplayPVIDsassignedtoge.2.1through6.Inthiscase,untagged
framesreceivedontheseportswillbeclassifiedtoVLAN1:
D2(su)->show port vlan ge.2.1-6
ge.2.1 is set to 1
ge.2.2 is set to 1
ge.2.3 is set to 1
ge.2.4 is set to 1
ge.2.5 is set to 1
ge.2.6 is set to 1
For information about... Refer to page...
show port vlan 7-7
set port vlan 7-8
clear port vlan 7-8
show port ingress filter 7-9
set port ingress filter 7-10
show port discard 7-10
set port discard 7-11
port‐string (Optional)DisplaysPVIDinformationforspecificport(s).Foradetailed
descriptionofpossibleport‐stringvalues,referto“PortStringSyntaxUsed
intheCLI”onpage 4‐1.