show port duplex
D-Series CLI Reference 4-11
Example
Thisexampleshowshowtosetge.3.3toaportspeedof10 Mbps:
D2(su)->set port speed ge.3.3 10
show port duplex
Usethiscommandtodisplaythedefaultduplexsetting(halforfull)foroneormoreports.
Syntax
show port duplex [port-string]
Parameters
Defaults
Ifportstringisnotspecified,defaultduplexsettingsforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythedefaultduplexsettingforGigabitEthernetport14in
slot 3:
D2(su)->show port duplex ge.3.14
default duplex mode is full on port ge.3.14.
set port duplex
Usethiscommandtosetthedefaultduplextypeforoneormoreports.Thiscommandwillonly
takeeffectonportsthathaveautonegotiationdisabled.
Syntax
set port duplex port-string {full | half}
Parameters
Defaults
None.
portstring (Optional)Displaysdefaultduplexsetting(s)forspecificport(s).
Foradetaileddescriptionofpossibleportstringvalues,referto
PortStringSyntaxUsedintheCLIonpage41.
portstring Specifiestheport(s)forwhichduplextypewillbeset.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntax
UsedintheCLIonpage41.
full|half Setstheport(s)tofullduplexorhalfduplexoperation.

Table of Contents