set system contact
2-24 Basic Configuration
set system contact
Usethiscommandtoidentifyacontactpersonforthesystem.
Syntax
set system contact [string]
Parameters
Defaults
Ifstringisnotspecified,thecontactnamewillbecleared.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtosetthesystemcontactstring:
D2(su)->set system contact “Joe Smith”
set width
Usethiscommandtosetthenumberofcolumnsfortheterminal connectedtotheswitch’sconsole
port.
Syntax
set width screenwidth [default]
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
ThenumberofrowsofCLIoutputdisplayedissetusingthesetlengthcommandasdescribedin
setlengthonpage225.
string (Optional)Specifiesatextstringthatcontainsthenameofthepersonto
contactforsystemadministration.
Note: A contact string containing a space in the text must be enclosed
in quotes as shown in the example below.
screenwidth Setsthenumberofterminalcolumns.Validvaluesare50to150.
default (Optional)Makesthissettingpersistentforallfuturesessions(writtento
NVRAM).