OPERATION
Figure 3.125: Height Sensitivity Change Screen
3.8.4 Case IH 5130/6130/7130, 7010/8010, 7120/8120/9120, and
7230/8230/9230 Combines
Checking Voltage Range from the Combine Cab (Ca se 8010)
NOTE:
Change
s m ay have been mad e to the combine controls or display since this document was published. Refer to
the co
mbine operator’s manual for updates.
To check the sensor output voltage range from the combine cab for Universal Display, follow these steps:
1. Position the header 6 in. (150 mm) above the ground, and unlock the adapter float.
2. Check that float lock linkage is on down stops
(washer [A] and nut [B] cannot be moved) at both
locations.
NOTE
:
If th
e header is not on down stops during the next
two
steps, the voltage may go out of range during
ope
ration causing a malfunction of the AHHC s ystem.
Fi
gure 3.126: Float Lock
147695 105 Revision A