Configuring the RF Signal
R&S
®
SMBV100B
327User Manual 1178.4460.02 ─ 03
Settings
State (RF frequency sweep)....................................................................................... 327
State (RF level sweep)................................................................................................327
State (LF frequency sweep)........................................................................................327
Current Frequency...................................................................................................... 328
Current Level...............................................................................................................328
Mode........................................................................................................................... 328
Retrace........................................................................................................................329
Shape..........................................................................................................................329
Spacing....................................................................................................................... 330
Dwell Time ..................................................................................................................330
Trigger Slope...............................................................................................................331
Execute Single Sweep ............................................................................................... 331
Show Connector..........................................................................................................331
Reset Sweep ..............................................................................................................331
State (RF frequency sweep)
Activates RF frequency sweep signal generation.
Note: Active sweep mode deactivates other sweeps or lists and vice versa.
Remote command:
[:SOURce<hw>]:FREQuency:MODE on page 824
State (RF level sweep)
Activates RF level sweep signal generation.
Note: Active sweep mode deactivates other sweeps or lists and vice versa.
Remote command:
[:SOURce<hw>]:POWer:MODE on page 872
State (LF frequency sweep)
Status of the LF frequency sweep signal.
You find this parameter in two dialogs:
"LF Frequency Sweep" turns on/off the signal generation.
See Sweep Mode Settings for access.
"Analog Modulation Sources" displays the current state (read-only). If it is turned
on, this dialog provides the varying sweep frequency, see Current Frequency.